Victron MultiPlus 12/1600/70-16
SKU: PMP122160000 Learn More»INVERTER CHARGER
Description
Victron MultiPlus 12/1600/70-16
The new style MultiPlus is set to replace the earlier MultiPlus Compact range. It is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology and a high-speed AC transfer switch in a single compact enclosure. In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
Specifications:
Wattage | 1600W |
---|---|
Peak Power | 3000VA |
Output Voltage and Frequency | 230VAC ±2% 50 Hz or 60Hz ± 0,1% (1) |
Input Voltage | 9.3 – 17V |
Operating Temperature Range | -40 to +65ºC (fan assisted cooling) |
Humidity | Max 95% (non-condensing) |
Dimensions (LxWxH) mm | 485 mm x 219 mm x 125 mm (H x W x D) |
Battery-connection | M8 bolts |
Protection category | IP21 |
Continuous Power at 25°C, Cos Phi 1 | 1300W |
Continuous Power at 40°C, Cos Phi 1 | 1200W |
Efficiency | 94% |
Net Weight (kg) | 12.0 Kg |
Features:
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years. The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
PowerControl - Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist - Boosting the capacity of shore or generator power
Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.
High start-up power
Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable relay
By default, the programmable relay is set as an alarm relay, i.e. the relay will de-energise in the event of an alarm or a pre-alarm (inverter almost too hot, ripple on the input almost too high, battery voltage almost too low).
Specifications
SKU PMP122160000
Brand Victron
GTIN 8719076044949
Product Category Power Inverter Chargers
Voltage 12V
Wattage (W) 1300
Input Voltage 9.5-17V
Dimensions 120 x 265 x 470mm
Peak Power (W) 2800
Weight (kg) 10.2
NOTE: see full product specifications & further product info in the Description section on this page.
Q & A
-
What size generator should I use for charging a battery?
The below generators are the minimum recommend sizes based on an AVR generator:
- 800VA 2KVA
- 1200VA 2.5KVA
- 1600VA 3KVA
- 3000VA 5KVA
- 5000VA 8KVA
If your generator is smaller than the recommended size for your inverter/charger, you will definitely need to adjust the settings on the inverter/charger and reduce the AC input current limit, and/or a DC charge current limit to prevent overloading the generator. If you do want an inverter based generator get one that is at least 30% larger than required than an equivalent AVR based model to help prevent overloads.
-
Can these chargers take solar input?
No, the battery charging component is an AC input, meaning only AC power (mains power) can charge through this unit.
-
How can I remotely monitor and control my devices?
You need a GX device to get remote monitoring. We recommend the Cerbo GX and an RJ45 UTP cable to connect it to the inverter. You can hardwire an ethernet connection to the unit, or connect it to a Wifi signal.
-
What size Generator can I use with the Multiplus Inverter Chargers?
The below generators are the minimum recommend sizes based on an AVR generator:
Inverter Charger Size Minimum Recommended Generator Size 240V AC Input Current Limit 800VA 2 kVa 5A 1200VA 2.5 kVa 7A 1600VA 3 kVa 10A 3000VA 5 kVa 16A 5000VA 8 kVa 25A If your generator is smaller than the recommended size for your inverter/charger, you will definitely need to adjust the settings on the inverter/charger and reduce the AC input current limit, and/or a DC charge current limit to prevent overloading the generator. If you do want an inverter based generator get one that is at least 30% larger than required than an equivalent AVR based model to help prevent overloads.
Reviews
Be The First To Review This Product!
Help other CARAVANRVCAMPING users shop smarter by writing reviews for products you have purchased.
Warranty
Warranty Period: 5 Years
Warranty Details: Please CLICK HERE for Warranty Information on this product
Delivery
- We ship Australia-wide with national road express freight companies such as Star Track, TNT and Toll.
- Small Items are sent with Australia Post via regular post.
- Delivery times are generally 3-5 days from day of dispatch for major cities (sometimes quicker). Please allow longer for regional and remote areas.
- Once your item(s) have been dispatched, we will provide you freight tracking information so you can track your delivery to your door.
- Items are fully insured during the freight process.
- Unfortunately we cannot deliver to PO Boxes.
- For further details on our Delivery Process you can visit our Delivery Page HERE.