Victron MultiPlus-II 48/3000/35-32 GX

SKU: PMP482306000 Learn More»
Victron MultiPlus-II 48/3000/35-32 GX
Free Shipping

INVERTER CHARGER

$1,090
$1,397
In Stock1-2 Days Dispatch

EXTRA $30 OFF! Add to cart to get an instant discount
SALE ENDS:

FREE SHIPPING

This item is sent via Express Courier. All freight is fully insured.

Accessories List:

Sold Out

$74

Sold Out

Click '+' to show more accessories

Description

Victron MultiPlus-II 48/3000/35-32 GX

 

The new style MultiPlus is set to replace the earlier MultiPlus Compact range. It is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology and a high-speed AC transfer switch in a single compact enclosure. In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.

Specifications:

Output Current Rating (Amps)                          35.0 Amps
Wattage 2400W
Peak Power 5500W
Output Voltage and Frequency 230 Vac ± 2% / 50 Hz ± 0.1%
Output Power 2400W (continuous output power at 25­­°C) | 2200W (continuous output power at 40­­°C) | 1700W (continuous output power at 65­­°C)
Input Voltage 38-66V
Operating Temperature Range -40 to +65°C
AC Input 187-265VAC | 45-65Hz
Inverter Output Continuous Watts 2400W (continuous output power at 25­­°C)
Charge voltage 'absorption' 57.6V
Charge Voltage Float - Wet (25 degrees)** 55.2V
Charge voltage 'storage' 52.8V
Inverter Output Nominal Efficiency 95% (maximum)
No load power consumption 11W | 2W in search mode
Product Dimensions (mm) LxWxH 147 x 275 x 506
Net Weight (kg) 18.0 Kg

 

Features:

Proven reliability

The full bridge plus toroidal transformer topology has proven its reliability over many years. The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.

PowerControl - Dealing with limited generator, shore side or grid power

With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.

PowerAssist - Boosting the capacity of shore or generator power

Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.

High start-up power

Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.

Search Mode

When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.

Programmable relay

By default, the programmable relay is set as an alarm relay, i.e. the relay will de-energise in the event of an alarm or a pre-alarm (inverter almost too hot, ripple on the input almost too high, battery voltage almost too low). 

 

Dometic Harrier Brochures

Dometic Harrier Operation Manual

Show More

Specifications

SKU PMP482306000

Brand Victron

GTIN 8719076046448

Product Category Power Inverter Chargers

Voltage 48V

Wattage (W) 2400

Input Voltage 38-66V

Dimensions 147 x275 x 506mm

Peak Power (W) 5500

Weight (kg) 19


NOTE: see full product specifications & further product info in the section on this page.

Q & A


  • Can these chargers take solar input?

    No, the battery charging component is an AC input, meaning only AC power (mains power) can charge through this unit.  

  • What size Generator can I use with the Multiplus Inverter Chargers?

    The below generators are the minimum recommend sizes based on an AVR generator:

    Inverter Charger Size Minimum Recommended Generator Size 240V AC Input Current Limit
    800VA 2 kVa 5A
    1200VA 2.5 kVa 7A
    1600VA 3 kVa 10A
    3000VA 5 kVa 16A
    5000VA 8 kVa 25A

    If your generator is smaller than the recommended size for your inverter/charger, you will definitely need to adjust the settings on the inverter/charger and reduce the AC input current limit, and/or a DC charge current limit to prevent overloading the generator. If you do want an inverter based generator get one that is at least 30% larger than required than an equivalent AVR based model to help prevent overloads.

Reviews

Be The First To Review This Product!

Help other CARAVANRVCAMPING users shop smarter by writing reviews for products you have purchased.

Write a product review

Warranty

Warranty Period: 5 Years

Warranty Details: Please CLICK HERE for Warranty Information on this product

Delivery

  • We ship Australia-wide with national road express freight companies such as Star Track, TNT and Toll.
  • Small Items are sent with Australia Post via regular post.
  • Delivery times are generally 3-5 days from day of dispatch for major cities (sometimes quicker). Please allow longer for regional and remote areas.
  • Once your item(s) have been dispatched, we will provide you freight tracking information so you can track your delivery to your door.
  • Items are fully insured during the freight process.
  • Unfortunately we cannot deliver to PO Boxes.
  • For further details on our Delivery Process you can visit our Delivery Page HERE.
 
Victron MultiPlus-II Inverter Charger 48/5000/70-50
Free Shipping
Victron MultiPlus-II Inverter Charger 48/3000/35-32
Free Shipping
Victron MultiPlus-II Inverter Charger 48/5000/70-50 GX
Free Shipping
Victron MultiPlus-II Inverter Charger 48/10000/140-100/100 230V